By installing an fm200 fire suppression system, you are protecting your assets and employees with one of the leading waterless fire protection systems available. Operation a magnet equipped float moves with the liquid level along the unit stem. Fm200 is a clean, colorless, and environmentally friendly fire suppression agent that is electrically nonconductive and safe for humans. About this manual this manual is intended to be a complete reference for the installation, operation, and service of the fike single hazard panel professional shp rpro fire alarmsuppression control system. Brochures b9110 shp pro b9110 shp pro portuguese datasheets d. This manual will assist the systems designer to properly design a fike micromist fire suppression. System in this manual system refers to the extinguishing equipment and does not include any detection system which may initiate an agent release. It extinguishes flames primarily through heat absorption, leaving no residue, thus minimizing downtime after a fire. This is a single volume technical manual arra nged in 6 sections, followed by an appendix. Fike proinert installation fire suppression manual by. Learn how the the fm200 clean agent fire protection system hfc227ea leaves no. Our clean agent fire protection system, which includes the use of hfc227ea and fm 200, leaves no residue and doesnt require costly cleanup, unlike sprinklers and other fire protection systems. In fact, the micromist system releases 100 times less water than traditional sprinkler systems, yet effectively extinguishes the fire.
As with previous fike systems, the impulse valve technology continues to allow for a. Fm200 fe227ea heptafluoropropane cf3chfch3 for speed in suppressing fires, reducing damages, saving on floor space and allowing visibility, fike is the clear choice. January, 2008 3 the installing contractor must have a minimum of five 5 years experience in the design, installation and testing of clean agent, or similar, fire suppression systems. Fike design, installation and maintenance manual pn 06215. Fm200 fire suppression system the grasshopper group. It includes cylinder, dip tube, discharge valve with pressure gaugeswitch, manual level release and the solenoid electrical actuator. Fm 200 fire suppression system orr protection systems. When used at standard design concentrations, it is safe for occupied spaces. Fm200 total flooding fire suppression system general the fm200 total flooding fire suppression system is an engineered system utilizing a fixed nozzle agent distribution network. This technical manual provides the necessary information for the design, installation, operation and maintenance of a chemetron fm200 sigma series engineered system. The physical and chemical properties of fm200 are not the same as. Safe for use in occupied areas at the design concentration, the system helps protect critical infrastructure and delivers effective asset protection.
For speed in suppressing fires, reducing damages, saving on floor space and allowing visibility, fike is the clear choice. A 360psi modular system is a single cylinder system using welded cylinders from 67 to 592 lbs. Fike is pleased to provide a design, installation and maintenance manual for our clean agent fire suppression systems w fm200 agent. Fikes clean agent fire suppression systems are great in applications ranging from telecommunications and data.
Sv series, mv series, lv series issued february 1, 2009. And it discharges in 10 seconds or less, extinguishing a fire. In applications where space is at a premium, fm200 fire suppression systems are the superior choice. That translates into less runoff, less damage and easy cleanup. Software key up to two extra per software package 0. Fm200 fire suppressant hfc227ea can be safely used where people are present. Fm200 is an important part of an environmentally responsible clean agent fire suppression solution with a zero ozonedepleting potential. Additionally, fm200 agent has the ability to absorb heat, further speeding up the suppression process. Manual or automatic actuators are available for release of the agent into the hazard area. The fm 200 agent is stored in cylinders as a liquid and pressurized with nitrogen, saving huge amounts of storage space. Introduction the clean agent fire master 200 fm200, heptafluoropropane is widely used as a substitute for halon. Introducing the new fike impulse valve used with fike. Fm 200 fire suppressant can be safely used where people are present.
Fm200 fire suppressant can be safely used where people are present. Halon 1 btm is an effective fire suppressant and has been widely used in total flooding gas protection system. Fm200 clean agent fire suppression system hfc227 fike. Troublefree design for safe and easy application compact, aesthetic and easy to move available in 2 cabinet sizes userfriendly standardized owners manual with every unit. The fm200 system stops fires fast by deploying quickly to prevent extensive damage, excessive repair costs, and delayed downtime for your business.
The system is designed and installed in accordance. The ansul fm200 clean agent fire suppression system is approved by factory mutual fm and listed by underwriters laboratories ul for class a, b and c fires. Fikes clean agent system uses fikes patented rupture disc valve design. Fikes proinert2 is the safest, most economical natural fire protection solution. And it discharges in 10 seconds or less, extinguishing a fire quickly and. Installation manual this product meets and exceeds the requirements of ul 325, the standard which regulates gate opener safety, as established and made effective march 1, 2000, by underwriters laboratories inc. The fm200 agent is stored in cylinders as a liquid and pressurized with nitrogen, saving huge amounts of storage space.
Fikes clean agent system with fm200 also known as hfc227ea, uses fikes patented rupture disc valve design offering additional flexibility, effectiveness and speed. Fike clean agent fire protection system, which includes the use of hfc227ea and fm200. Acoma drive, suite 106 scottsdale, az 85260 usa telephone. Upon installation, the cylinders shall be secured using either cylinder straps or. Refer to fike hfc227ea fm200 instruction manual for liquid level indicator lli, pn 06107. Level readout is obtained by simply removing the protective cap and pulling out a calibrated tape until magnetic interlock with the float. Similar to halon 1, fm200 agent extinguishes class a,b, and c fires by interrupting the chemical chain reaction. Maintenance manual for the clean agent fire extinguishing system employing fm200 shall be submitted after complete installation. The primary extinguishing mechanism of fm200 is heat absorption, with a secondary chemical contribution from the thermal decomposition of fm200 in the flame. Conventional fire alarm and suppression system fike. Our clean agent fire protection system, which includes the use of hfc227ea and fm200, leaves no residue and doesnt require costly cleanup, unlike sprinklers and other fire protection systems.
This makes it a suitable choice for new installations using total flooding systems, and for halon 1 replacement applications. Pdf fike fire alarm manual cheetah trouble codes read. In other words, when you opt for fm200 as compared with other halon alternatives agents, less agent can do the same job. Impulse technology efficient and cost effective as with previous fike systems, the impulse valve technology continues to allow for a flexible, modular des. Fike fm200 clean agent fire suppression system with the shp pro control panel fm200 system w shp pro specification page 2 of 8 pn. Fm 200 suppression systems historically, the most widely used halon 1 replacement, fm 200 provides waterless fire suppression without leaving behind residue or particulate, and has been installed in over one hundred thousand applications in more than 70 nations. Fm200 is an odorless, colorless, liquefied compressed gas. Description date size cheetah for the same price as a. Design, installation maintenance manualfm200fike gases. The clean agent fire extinguishing system shall consist of fm200, agent cylinders, 1800. Electric manual actuation impulse valve operator ivo for detailed.
820 157 1236 1129 1024 1287 892 282 818 296 257 173 1132 1010 672 1258 246 1593 669 1300 1090 343 1574 763 1615 1038 1 432 487 686 491 982 664 24 225 1320 584 115 677 1251 772 1107 640